Econ. Environ. Geol. 2022; 55(4): 407-419
Published online August 30, 2022
https://doi.org/10.9719/EEG.2022.55.4.407
© THE KOREAN SOCIETY OF ECONOMIC AND ENVIRONMENTAL GEOLOGY
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided original work is properly cited.
Soil(vadose zone) gas compositions were measured for about 3 days to suggest a method for monitoring and interpreting soil gas data collected around wells from which methane(CH4) is outflowing. The vadose zone gas samples were collected within 1 m around two test wells(TB2 and TB3) at Pohang and analyzed for CO2, CH4, N2 and O2 concentrations in situ. CO2 flux was measured beside TB2. In addition, gas samples from well head in TB2 and atmospheric air samples were collected for comparison. Carbon isotopes of CO2(δ13CCO2) of samples collected on the last day of the study period were analyzed in the laboratory. The two test wells (TB2 and 3) were 12.7 m apart and only TB3 was cemented to the surface. According to the bio-geochemical process-based interpretation, the relationships between CO2 and O2, N2, and N2/O2 of vadose zone gas were plotted between the lines of CH4 oxidation and CO2 dissolution. In addition, the CH4 concentrations of gas samples from the wellhead of the uncemented well (TB2) were 5.2 times higher than the atmospheric CH4 concentration. High CO2 concentrations (average 1.148%) of vadose zone gas around TB2 seemed to be attributed to the oxidation of CH4. On the other hand, the vadose zone CO2 around the cemented well(TB3) showed a relatively low concentration(0.136%). This difference indicates that the vadose zone gas(including CO2) around the CH4 outflowing well were strongly affected by well completion(cementing). This study result can be used to establish strategies for environmental monitoring of soil around natural gas sites, and can be used to monitor leakage around injection and observation wells for CO2 geological storage. In addition, the method of this study is useful for soil monitoring in natural gas storage and oil-contaminated sites.
Keywords methane oxidation, shallow depth gas field, soil CO2, soil gas monitoring, well completion
채기탁1,* · 김찬영1,2 · 주가현1 · 박권규1 · 노열3 · 이창현1 · 염병우1 · 김기배4
1한국지질자원연구원
2지오그린21
3전남대학교
4KNJ 엔지니어링(주)
메탄(CH4)이 유출되는 관정 주변에서 토양(비포화대) 가스 모니터링과 자료 해석 방법을 제시하고자 토양 가스의 성분변화를 약 3일간 측정하였다. 이를 위해서 포항 지역의 시험 관정 2개(TB2, TB3)의 주변 1 m 이내에서 방사상으로 토양 가스를 채취하고 현장에서 CO2, CH4, N2, O2의 농도를 분석하였다. TB2의 관정 정두(wellhead)에서 30 cm 떨어진 지점에서 CO2 플럭스도 측정하였다. 아울러 TB2 관정 정두의 가스 시료와 대기 시료도 채취하여 분석하였다. 모니터링 마지막 날 채취한 시료는 실험실에서 CO2의 탄소동위원소(δ13CCO2)를 분석하였다. 서로 12.7 m 떨어져 있는 두 시험 관정 중 TB3는 시멘팅이 되어 있고, TB2는 시멘팅이 되어 있지 않았다. 생지구화학 반응 기반(process-based) 해석을 적용한 결과, 비포화대 가스의 CO2, O2, N2 농도와 N2/O2 의 변화는 모두 CH4의 산화를 지시하는 선과 가스의 용해에 의한 농도의 변화를 지시하는 선 사이에 위치하고 있었다. 또한 TB2 정두에서 측정된 CH4은 대기의 CH4에 비해서 5.2배 높은 값을 나타나고 있었다. 시멘팅이 되어 있지 않은 관정(TB2) 주변 비포화대에서 나타난 높은 CO2 농도(평균 1.148%)는 CH4의 산화에 의해 증가한 것으로 판단된다. 반면, 시멘팅이 된 관정(TB3) 주변의 비포화대 CO2는 상대적으로 낮은 농도(0.136%)를 나타내고 있었다. 따라서 CH4가 산출되는 관정의 주변 토양가스(CO2 포함)는 관정의 완결 상태(시멘팅)에 크게 영향을 받는 것으로 판단된다. 본 연구는 천연가스 개발 관정 주변 토양의 환경 모니터링을 위한 전략 수립에 활용될 수 있으며, CO2 지중저장을 위한 주입정 및 관측정 주변 누출 감시에 활용될 수 있다. 또한 본 연구의 방법은 천연가스 저장소, 유류 오염 토양의 모니터링에 활용 가치가 있다.
주요어 메탄 산화, 천부 육상 가스전, 토양 CO2, 토양 가스 모니터링, 관정 완결
Soil CO2 could be originated from CH4 oxidation around wells discharging CH4, which is strongly affected by well completion.
Negative relationships between CO2 and CH4 in soil gas with time showed CH4 oxidation.
The relationships between CO2 and O2, N2, and N2/O2 of soil gas revealed that CO2 dissolved in rain water after CH4 oxidation.
비포화대(토양)는 지질권, 생물권, 대기권이 겹쳐있는 경계로서 다양한 환경-지구화학 반응이 발생하는 복잡한 시스템이다. 게다가 인간의 생활, 산업, 농업 활동에 영향을 주고받으며 심각한 변화를 겪고 있다. 특히 비포화대의 가스는 자연적이든 인위적이든 지질권에서 배출되는 가스가 최종적으로 거치는 통로이며, 대기와 소통하고, 생물의 활동에 의해 변화하며, 반대로 생물의 활동에도 영향을 준다. 그동안 지질학 분야에서 비포화대 가스에 관한 연구는 주로 화산 감시와 화산 가스의 총 배출량을 추정하기 위해 수행되었다. 최근에는 화산 관련 연구에서 개발된 비포화대 가스 연구 방법이 이산화탄소지중저장 관련 연구, 단층지역 가스 유동 연구에 응용되었다(Jones
본 연구는 CO2 지중저장 모니터링 관련 시험을 위해 시공된 관정 주변(Fig. 1의 TB2와 TB3)의 비포화대 가스를 조사하는 중에 관정 정두에서 메탄가스(CH4)가 관찰되었으며, 이에 의한 비포화대 CO2의 변화가 인지되어 시작되었다. 우리나라 육상에서는 대규모의 가스전이 발견된 사례가 없어서, 가스 개발 관정 주변 환경 모니터링에 대한 필요성이 없었다. 그러나 2017년 3월 포항시 남구에 공원 조성을 위해 지하수 관정을 굴착하던 중에 천연가스에 의한 화재가 발생하여 소규모 육상 가스전이 확인되었다(신정균 외, 2019; 황인걸 외, 2019). 포항 일대에서는 지하수에서 메탄의 부존이 드물지 않게 보고되었으나(Lee
메탄가스 생산 관정 주변의 토양에서는 CH4의 산화에 의해 CO2 농도가 증가할 가능성이 있다. Romanak
본 연구는 CH4가 부존된 지역에서 토양 가스 모니터링과 해석 방법을 제시하고자 수행되었다. 이를 위해서 CH4가 배출되는 것으로 의심되는 시험 관정 주변의 약 1 m 내외에서 비포화대 가스 시료를 채취하여 성분 및 탄소동위원소를 약 3일간 3시간 간격으로 분석하였다. 이 연구는 우리나라에서는 처음으로 CH4 부존 지역의 토양가스를 연구한 결과이며, 연구 결과는 CO2 지중저장 관련 사업, 천연가스 저장소 주변 토양, 유류로 오염된 토양의 가스 모니터링 방법에 응용될 수 있을 것으로 기대된다.
연구 지역은 경상북도 포항시 북구 흥해읍 성곡리에 위치한 한국지질자원연구원 포항지질자원실증연구센터 내에 조성된 시험 부지로, TB2와 TB3 관정 주변이다(Fig. 1a). 연구지역은 제 3기 마이오세 반고결 이암층으로 이루져 있는 두호층에 분포하며, 두호층 하부에는 제 3기 에오세 쇄설성 화산암류가, 더 아래로는 백악기 기반암(안산암질 화산암류 및 쇄설성 퇴적암류)이 존재한다. TB2의 시추코어를 분석한 결과 전체적으로 회색을 띠는 이암이 우세하게 존재하는 가운데, 고화도가 불량한 사질층과, 역을 포함하는 사질층이 협재한다(KIGAM, 2014). 지표로부터 87 ~ 93 m, 235 ~ 238 m, 307 ~ 312 m 심도에 사질층이 협재한 구간이 시추코어에서 확인되었다. Lee
TB2와 TB3는 시험 관정으로서, 약 12.7 m 떨어져 있다. TB2 관정의 총 심도는 329.7 m 이고, 302.7 m 하부는 스크린이 설치되어 있다. TB2 관정은 바닥까지 케이싱이 설치되었고, 케이싱 외부는 시멘팅이 안 되어 있다. TB3 관정은 총 심도가 405 m 이고 하부까지 케이싱이 설치되었다. 320 m 하부에 스크린이 설치되어 있고, 심도 150 m 까지는 gravel packing이 되었으며, 150 m 상부는 시멘팅이 되어 있다. TB3는 케이싱 상부 정두에 가스의 누출 방지장치가 설치되어 있다.
연구 기간(2019년 4월 27일부터 30일) 7일 전(4월 20일)부터 연구 종료 때까지 기상자료를 Fig. 1b에 도시하였다. 기상자료는 연구지역과 가장 가까운 기상청의 포항 AWS(automatic weather system) 자료이다. 연구 시작 직전인 4월 26일은 6.3 mm의 약한 강우가 있었고, 27일 새벽 2시 30분에 그쳤다. 그리고 4월 29일 11시 20분에 강우가 시작되어 29일 23시까지 45.9 mm의 비교적 강한 강우가 있었다(Fig. 1b). 27일에는 비가 그친지 7시간 30분 후에 시료채취 및 분석을 시작하였고, 29일과 30일에는 비가 그친지 11시간 후에 시료채취 및 분석을 재개하였다. 따라서 본 연구 기간은 토양 가스가 강우의 영향을 받은 기간에 수행되었다고 할 수 있다.
연구 기간 중 기온은 9.6 ~ 18.3 °C, 상대습도는 44.6 ~ 100.0%, 해면기압은 1007.3 ~ 1023.3 hPa로 변화를 보였다. 특히 기압은 연구 기간 내내 감소하는 추세를 나타내었다. 기온, 상대습도, 기압은 CO2 플럭스 측정 시 동시에 측정되기 때문에 AWS 자료보다는 현장에서 측정된 값을 해석에 이용하였다(2.3절 참조).
비포화대 가스는 2019년 4월 27일 오전 10시부터 30일 19시까지 3시간 간격으로 21회 채취하였다. 4월 29일 오전 11시부터 비가 오기 시작하여 7회(24시간) 시료 채취를 못하였으며, 4월 30일 10시부터 재개하여 19시에 종료하였다. 비포화대 가스 시료 채취를 위해서 AMS gas probe(AMS, Inc., USA)를 이용해서 약 60.4(±2.6) cm를 굴착하여 비포화대 가스 샘플링관(PFA(perfluoroalkoxy)재질, ID 0.44 cm)을 시료 채취 하루 전(4월 26일)에 설치하였다(Fig. 1a). 관정 주변은 잔돌로 약 50 cm 덮여있었기 때문에 잔돌 층을 제거하고 AMS gas probe를 설치하였다. 비포화대 가스 샘플링관 끝에는 화살촉 모양의 스테인리스 재질의 첨두가 있고, 이는 토양 입자의 유입을 방지하기 위한 스테인리스 망(mesh #50)으로 감싸여있다. 또한 지표의 대기 유입을 막기 위해서 fluoropolymer 재질의 둥글고 얇은 우산모양 판을 샘플링관과 첨두 사이에 설치하였다. 샘플링관은 TB2 관정 주변에 12개, TB3 관정 주변에 4개 설치되었다(Fig. 1a). TB2 주변에 설치된 샘플링관은 북쪽에서부터 시계 방향으로 V1부터 V8로 명명하였으며, TB3 주변의 샘플링관은 북쪽에서부터 시계방향으로 V9부터 V12로 명명하였다(Fig. 1a).
비포화대 가스는 설치된 샘플링관을 통해 지상에서 연동펌프(Masterflex E/S, Cole-Parmer Instrument, USA)로 1분간 관 내부에 고인 가스를 제거한(purging) 후 약 50 mL를 Tedlar bag에 담았다. 연동펌프의 유량은 약 80 mL/min으로 유지하였다. 시료 채취는 3시간 간격으로 정시에 1번 관(V1)부터 시작하여 12번 관(V12)까지 수행되었으며, 1회 소요 시간은 약 30분 정도 걸렸다. V12에서는 물이 유입되어 연구 기간의 마지막에만 시료를 채취/분석하였다.
본 연구에서는 비포화대 가스 외에 TB2 관정의 정두에서 가스를 채취하였으며, 비포화대 가스와 대기가 혼합되었는지 파악하기 위하여 대기 시료도 채취 하였다. 정두 가스 시료는 정두의 관정 캐이싱 내부에 시료 채취용 튜브를 약 20 cm 넣어 채취하였고, 대기 시료는 TB2 위치에서 지상 약 100 cm 상부에서 채취되었다. 정두 가스 시료는 비포화대 가스 시료 채취 시 매번 채취하였으나, 대기 시료는 약 12시간마다 한 번 채취(6회)하였다.
비포화대 가스, TB2 관정의 정두 가스, 대기 시료의 주요 성분인 N2, O2, CO2, CH4의 농도는 QMS(quadrupole mass spectrometer: Pfeiffer Vacuum, 독일) OmnistarTM(GSD320 gas analysis system)를 활용하여 현장에서 시료 채취 후 즉시 분석하였다. QMS 장비의 기체 시료 주입관에 Tedlar bag을 연결한 후, 5분 이상 가스를 흘려주고 마지막의 농도 값을 읽어 기록하였다. QMS는 가스 질량분석기로서 장비에 주입된 가스를 구성하는 분자를 이온화 하고, 4중극자 질량 필터(quadropole mass filter)에서 가스의 각 이온을 질량/전하 비율(mass/charge)로 분리하여 이온 검출기(ion detector)로 각 이온의 이온 전류(ion current)를 측정한다. 측정된 이온 전류는 표준시료로 보정을 거쳐 부피%로 나타낸다. 본 연구에서는 국내에서 제조된 표준가스시료(N2 = 74.02%, O2 = 19.98%, CO2= 5.00%, CH4 = 1.00% Rigas©, Korea)로 보정하였으며, 표준시료를 9회 분석하여 보정 값을 유지하고 있는지 확인하였다. 그 결과 N2, O2, CO2는 각각 0.1%, 0.5%, 0.5% 정도만 참값에서 벗어났고, CV(coefficient of variation)는 각각 0.4%, 0.7%, 1.5%로 정밀도가 매우 좋았다.
반면 CH4는 보정 후 표준시료 분석에서 평균 4.9% 벗어나 있으며, CV는 10.4%로 상대적으로 정밀도가 떨어졌다. CH4의 이온화된 가스 분자의 주된 amu(atomic mass unit)는 16, 15(amu 16에 대한 이온강도 비율 85.8%)인데 amu 16의 경우 CH4가 O2, CO2, H2O 등과 amu를 공유하고 있으므로 O2, CO2, H2O의 성분이 높은 혼합 가스의 경우 CH4가 과평가 될 수 있다. 따라서 CH4는 amu 15로 분석하였다(Freifeld and Trautz, 2006). 이와 같이 QMS 분석에서는 한 종류의 가스분자에서 파생된 amu가 다른 분자와 동일한 amu를 나타낼 수 있으므로, 다성분 가스와 여러 원소로 구성된 가스, 질량이 무거운 가스가 많을수록, 가벼운 가스 성분의 농도 측정에 영향을 미칠수가 있다. 초고순도 N2를 공시료(blank sample)로서 분석한 CH4의 기기검출한계(IDL: instrument detection limit)는 0.014%이다. 이는 일반적인 대기의 CH4 농도인 1.7 ~ 1.9 ppmv(NOAA, 2022; Wuebbles and Hayhoe, 2002)에 비해서 높은 값이다. 따라서 본 연구에서는 토양 CH4의 농도(S)를 현장에서 측정한 대기 CH4 농도(A)의 비례값(S/ACH4)으로 나타내었다. 본 연구의 주안점은 토양 CO2 모니터링이기 때문에 토양 CH4에 대해서는 정량적인 해석보다는 CO2 농도에 연관하여 정성적으로 해석하였다.
연구 기간의 마지막 날(2019년 4월 30일 19:00) 채취한 비포화대 가스 시료는 대전의 한국지질자원연구원으로 운송하여 탄소동위원소(δ13CCO2)를 분석하였다. CO2의 탄소 동위원소 분석은 CRDS(cavity ringdown spectroscopy: Picarro 사(社) G2121-i)를 이용하였으며(Park
지표에서 배출되는 CO2의 유량인 플럭스는 미국 Li-COR 사의 Li-8100A로 측정하였다(Park
본 연구에 활용된 통계분석은 통계 프로그램 R로 수행하였다(R core team, 2018). 두 변수간의 선형관계는 상관분석(correlation analysis)을 통하여 수행하였고, 상관계수(r)로 나타내었다. 상관분석은 조사기간 초기 결측값을 제외하고 강우 이전인 4월 27일 16시부터 29일 10시까지 자료들을 대상으로 하였다.
그룹간의 차이를 정량적으로 평가하기 위해 Mann-Whiteny U test를 수행하였다. Mann-Whiteny U test는 독립적인 두 그룹의 자료의 순위를 각각 구한 후 순위의 평균을 비교하는 비모수 통계분석이다(Chae
TB2와 TB3 주변의 심도 약 60 cm 비포화대에서 채취된 가스 시료, TB2 관정 정두에서 채취된 가스 시료, 대기 시료의 QMS 및 CRDS 분석 결과의 기초 통계를 Table 1에 나타내었다. 비포화대의 CO2 평균은 0.871%이고, 최대값은 2.612%(=26,120 ppmv)이다. 특징적으로 비포화대 N2(평균 80.1%)는 대기(78.7%)보다 높고, O2(19.0%)는 대기(21.2%) 보다 낮다. TB2 인근 비포화대(V1~8) CO2 평균은 1.148(±0.205%), TB3인근 비포화대(V9~10) 평균은 0.136(±0.088%)로 뚜렷하게 구분된다. 비포화대 가스의 S/ACH4(대기 CH4에 대한 비율) 평균은 1.0이고, 0.8 ~ 1.2 사이에서 변화한다. 비포화대의 CH4 농도는 대기와 비슷한 수준인 것으로 평가된다. TB2 주변의 S/ACH4 는 1.0이고, TB3 주변은 0.9이다(Table 1). Mann-Whitney U test 결과 p 값은 0.000(2.85E-5)으로 TB2가 TB3 보다는 높다고 평가 할 수 있다.
Table 1 Statistics of vadose zone gas, wellhead gas, and air samples collected around test wells in Pohang area
CO2(%) | S/ACH41) | N2(%) | O2(%) | δ13CCO2(‰)2) | ||
---|---|---|---|---|---|---|
Vadose | Average | 0.871 | 1.0 | 80.1 | 19.0 | -18.0 |
zone gas | Stdev.3) | 0.725 | 0.1 | 1.5 | 2.2 | 8.0 |
(n=232) | Minimum | 0.059 | 0.8 | 78.0 | 12.1 | -25.2 |
Maximum | 2.612 | 1.2 | 85.3 | 21.5 | -4.1 | |
Vadose zone gas around TB2 | Average | 1.148 | 1.0 | 80.6 | 18.3 | -23.2 |
Vadose zone gas around TB3 | Average | 0.136 | 0.9 | 78.8 | 21.1 | -7.5 |
Wellhead | Average | 0.076 | 5.2 | 78.7 | 21.1 | |
gas at TB2 | Stdev.3) | 0.015 | 3.5 | 0.1 | 0.2 | |
(n=19) | Minimum | 0.065 | 1.6 | 78.2 | 20.7 | |
Maximum | 0.136 | 14.0 | 78.9 | 21.6 | ||
Air | Average | 0.081 | 1.0 | 78.7 | 21.2 | -9.2 |
(n=6) | Stdev.3) | 0.071 | 0.1 | 0.1 | 0.1 | |
Minimum | 0.068 | 0.9 | 78.6 | 21.2 | ||
Maximum | 0.114 | 1.1 | 78.7 | 21.4 |
1) The ratio of CH4 concentration to the average CH4 of air samples.
2) Carbon-13 isotope of CO2 expressed in the δ(‰) notation relative to the V-PDB(Vienna Peedee Belemnite) standard.
3) Standard deviation.
조사의 마지막(2019년 4월 30일 19:00)에 채취된 비포화대 가스의 δ13CCO2는 평균 –18.0‰(–25.2 ~ -4.1‰)로 나타났다. TB2 인근 V1~8의 평균은 –23.2(±2.0‰), TB3 인근 V9~10의 평균은 –7.5(±2.8‰)로 CO2 농도와 마찬가지로 뚜렷하게 구분된다. 최대값인 –4.1‰(V10)은 대기 시료의 δ13CCO2(–9.2‰)보다 높은 특징이 있다. TB2의 정두에서 채취된 가스의 CO2 평균은 0.076%이고, S/ACH4의 평균은 5.2로 대기보다 5배 높은 CH4 농도를 나타낸다(Table 1). 대기의 CO2 평균 농도는 0.081%로 정두에서 측정된 CO2 농도와 차이나지 않았다(Mann-Whitney U test 결과 p = 0.333).
TB2 관정에서 30 cm 떨어진 곳에서 측정된 CO2 플럭스의 평균은 3.5 g/m2/d이다(Table 2). 시간에 따른 플럭스의 변화는 3.2.2절에 설명되어 있다. CO2 플럭스 측정중에 동시에 측정된 surface CO2의 평균은 0.048%로 QMS로 분석된 대기 CO2의 평균값(0.081%)보다 낮다. QMS로 분석한 CO2는 5.0% 표준시료로 보정한 값이다. 따라서 0.1% 미만의 낮은 CO2 농도는 분석기기의 오차가 반영되었을 수 있다. Fig. 2에서 제시된 CRDS와 QMS의 CO2 농도 상관관계 식(CRDS = 0.9921 × QMS – 0.022)에서 QMS 분석 결과가 CRDS 분석 결과에 비해 약 0.02% 높게 측정되었음을 알 수 있다. CO2 플럭스 측정 전에 측정된 대기의 온도(Temp.)는 10.5oC에서 23.9°C(평균 14.5°C), 상대습도(RH)는 36.2%에서 89.7%(평균 68.0%)로 일교차가 심하였다(Table 2). CO2 플럭스 측정 중에 측정된 챔버 내부의 대기압(Ps)은 982.4 hPa에서 997.9 hPa 범위를 나타냈으며, TB2의 지하수위 심도는 25.36 m에서 25.52 m로 16 cm 변동하였다(Table 2).
Table 2 Statistics of CO2 flux measured beside the test well (TB2) in Pohang (n=19). Surface CO2, temperature, relative humidity, air pressure were also measured during CO2 flux measurement
CO2 flux (g/m2/d) | Surface CO21)(%) | Temp.2)(°C) | RH3)(%) | Ps4)(hPa) | Depth to water table of TB2 (m) (n=22) | |
---|---|---|---|---|---|---|
Average | 3.5 | 0.048 | 14.5 | 68.0 | 992.8 | 25.44 |
Stdev.5) | 1.0 | 0.002 | 3.5 | 13.2 | 5.0 | 0.04 |
Minimum | 2.2 | 0.046 | 10.5 | 36.2 | 982.4 | 25.36 |
Maximum | 5.3 | 0.051 | 23.9 | 89.7 | 997.9 | 25.52 |
1) The average CO2 concentration measured for 2 minutes during CO2 flux measurement.
2) Air temperature measured in the pre-purging stage before CO2 flux measurement, which represents the atmospheric temperature.
3) Relative humidity measured in the pre-purging stage before CO2 flux measurement, which represents the atmospheric relative humidity.
4) The average air pressure measured for 2 minutes during CO2 flux measurement. Since the pressure inside the chamber remains constant during the CO2 flux measurement, this value can be considered as the air pressure measured in the field.
5) Standard deviation.
TB2와 TB3 주변의 비포화대 CO2의 농도를 Fig. 3a에 나타내었다. TB2 주변 V1~8은 4월 28일 19시 이전에는 공통적인 경향이 뚜렷하지 않았으나, 4월 28일 19시 이후부터 일률적으로 증가하는 양상을 나타냈다(Fig. 3a). 비가 그친 4월 30일 10시 이후에는 V1~8 간에 공통적인 경향이 나타나지 않았다. Fig. 3c에는 V1~8의 평균과 표준편차를 나타내었다. 4월 28일 19시 이후부터 표준편차가 줄어드는 것을 확인할 수 있다. 표준편차가 크지만 대체로 매일 16시까지 비포화대 CO2는 감소하다가 16시 이후부터 다음날 오전 10시까지 증가한 후 다시 감소하는 일변화 경향을 나타낸다(Fig. 3c).
비포화대 S/ACH4의 변화를 Fig. 3b에 나타내었다. S/ACH4는 시간에 따라 감소하는 경향을 나타내다가 비가 그친 후(4월 30일 10시) 다시 증가한다. CO2에 비하여 가스 시료 채취 위치 간의 차이가 적다. Fig. 3c에는 TB2 인근 V1~8의 S/ACH4 평균과 표준편차를 나타내었다. 그 결과 CO2의 변화와는 약간의 시간차를 두고 반대로 나타나고 있다. CO2와 S/ACH4의 상관계수는 –0.74(p<0.05)이다.
비포화대 N2와 O2 의 변화를 Fig. 3d와 e에 각각 나타내었다. Fig. 3f에는 V1~8까지의 평균과 표준편차를 나
타내었다. N2는 야간에 증가하고 주간에 감소하여 CO2와 유사한 변화를 나타내고, O2의 농도는 그 반대의 경향을 나타내고 있다. V1~8 평균 N2와 CO2의 상관계수(correlation coefficient, r)는 0.96(p<0.05), O2와 CO2의 상관계수는 –0.98(p<.05)이다. 비포화대의 CO2, S/ACH4, N2, O2 가스 성분의 변화는 서로 밀접한 상관관계가 있다.
정두에서 채취된 가스 시료의 시간에 따른 변화는 Fig. 4에 나타내었다. CO2 농도는 4월 29일 4시에 0.136%를 제외하면 비교적 일정하게 유지되었다(Fig. 4a). 반면 S/ACH4, N2, O2 농도는 시간에 따라 증감하는 양상이 나타난다(Fig. 4a, b). S/ACH4는 N2와 정의 상관성(r=0.59, p<0.05), O2와 부의 상관성(r=-0.91, p<0.05)을 나타내었다.
시간에 따른 CO2 플럭스의 변화와 플럭스 측정기로 측정된 surface CO2, 대기의 온도(Temp.)와 상대 습도(RH), 압력(Ps) 및 TB2의 지하수위 심도를 Fig. 5에 나타내었다. CO2 플럭스는 주간에 증가하고, 야간에 감소하는 일변화를 나타낸다(Fig. 5a). CO2 플럭스는 surface CO2와는 부의 관계(Fig. 5a, r=-0.51, p<0.05), 대기 온도와는 정의 관계(Fig. 5b, r=0.39, p=0.15), 대기 상대 습도와는 부의 관계(Fig. 5c, r=-0.56, p<0.05), TB2 지하수 수위 심도와는 부의 관계(Fig. 5e, r=-0.26, p=0.34)를 나타낸다. CO2 플럭스와 온도, 수위 심도는 Fig. 5b와 5e에서는 상관관계가 있는 것으로 보이나 상관계수는 낮게 나타났다. 상관계수는 2.4장에서 설명하였듯이, 비가 온 기간과 조사 초기 시점의 결측값을 제외한 통계분석 결과이어서 그래프에서 보이는 것보다 상관관계가 낮게 평가된 것으로 판단된다.
연구 지역 TB2, TB3 관정 인근 비포화대에서 채취된 가스의 CO2-O2, N2-CO2, N2/O2-CO2 간의 관계를 Fig. 6에 나타내었다. Fig. 6은 Romanak
CH2O + O2 = CO2 + H2O (식 1)
CH4 + 2O2 = CO2 + 2H2O (식 2)
Fig. 6에서 비포화대 가스 성분은 미생물의 호흡(biological respiration)을 나타내는 지시선보다 메탄 산화(oxidation of CH4)를 나타내는 지시선에 더 가깝다. 게다가 정두에서 채취된 가스의 CH4는 대기의 CH4보다 평균 5.2배 높고, 최대 14배 높게 나타났다(Table 1). 대기의 CH4가 1.8 ppmv이라고 한다면, 정두에서 측정된 CH4는 250 ppmv 정도로 높다. 따라서 CH4가 산화되어 CO2가 발생했을 가능성이 충분하다. Romanak
본 연구에서 분석한 비포화대 CH4 농도는 분석 한계에 근접한 값을 나타냈기 때문에 대기 시료의 CH4 평균값에 대한 비율(S/ACH4)로 해석하였다(2.2.3 절 참조). Romanak
토양 미생물이 O2로 호흡을 하고 C3 식물을 분해하는 대사과정(식 1)에서 발생한 CO2의 탄소동위원소는 -34 ∼ -23‰ 범위로 알려져 있다(Faure, 1998). TB2 주변 비포화대 CO2의 δ13CCO2의 평균값은 –23.2‰ 이기 때문에 CO2의 기원을 미생물의 호흡으로 해석할 수도 있다. CH4 산화가 발생하면 용존 CO2의 탄소동위원소는 값은 오히려 낮아지는 것으로 알려져 있다(Clark and Fritz, 1997; Kotelnikova, 2002). Park
CH4 산화로 생성된 CO2가 충진되는 강우에 용해되어 δ13CCO2가 높아졌을 가능성이 있다. 토양으로 충진되는 강우의 pH를 측정하지는 못 했으나(4월 26일 ~ 27일), pH가 5.5보다 낮을 경우 εDIC-CO2는 약 –1‰(14.5oC) 정도이기 때문에(Chae
앞서 설명한 바와 같이 발생된 CO2는 토양층을 거처 지하수로 충진되는 강우에 용해될 수 있다(Romanak
혼합되는 정도에 따라서 가스 성분의 농도가 결정되는 것으로 판단된다.
한편, TB3 주변 비포화대의 CO2는 CH4의 산화가 아닌 대기와의 혼합이 크게 영향을 미쳤다고 할 수 있다. 그러나 TB3 인근 비포화대의 δ13CCO2는 1개 시료를 제외하고 모두 대기 시료의 –9.2‰보다 높다(Fig. 7). 이는 4.2 절에서 설명한 바와 같이 open system에서 CO2의 용해에 의해 잔류 CO2의 동위원소 값이 높아진 것으로 판단된다. TB3 주변의 비포화대 가스의 CO2 농도는 TB2보다 낮고(Fig. 8), V9를 제외하면 대기의 CO2 농도와 비슷하다. 따라서 TB3 주변 비포화대 CO2는 CH4의 산화나 미생물의 호흡에 의한 CO2 보다는 대기의 혼합 비율이 높고, 강우에 용해된 결과로 판단된다.
한편 용존 CH4는 미생물에 의해 산소와 황산염이온과 반응하여 산화 될 가능성이 있다(Clark and Fritz, 1997; 식 3, 4). CH4 + 2O2 = HCO3- + H2O + H+ (식 3) CH4 + SO42- = HCO3- + HS- + H2O (식 4) 2017년 9월 5일 심도 약 300 m에서 채취된 TB2 관정의 물 시료의 용존산소는 2.2 mg/L, SO4 이온은 258 mg/L 로 분석된 바 있다. 특히 HS- 농도가 4 μg/L로 나타난 바 있다. 따라서 용존 CH4이 산화되어 용존 탄산염이 되고(식 3, 4), 용존 탄산염이 탈기되어 비포화대에 유입될 가능성도 고려해 볼 필요가 있다. 그러나 물 시료의 pH가 9.0이고, DIC가 0.5 mmol/L, PCO2가 0.03 atm으로 낮은 점으로 보아 용존 CH4가 산화되었다고 해도 CO2가 탈기되어 대수층에서 비포화대로 이동했을 가능성은 없다. 게다가 연구지역의 지표 부근은 두꺼운 이암층(2.1.절)이 분포하고 있어서 대수층에서 탈기에 의해 CO2가 비포화대로 유입될 가능성은 낮은 것으로 판단한다. 따라서 본 연구에서 TB2 관정 인근 비포화대의 CO2는 TB2 관정에 고인 물에서 탈기된 CH4이 산화되어 CO2가 되고, CO2가 주변 비포화대로 퍼진 결과로 판단된다. 특히 TB2 관정의 수위심도는 25.4 m로 낮고(Fig. 5e), 관정 케이싱 외부에 시멘팅이 안 되어 있는 점은 위 주장에 신빙성을 더하고 있다.
반면 TB3 관정은 바닥에서 상부까지 시멘팅이 되어 있고 정두에 누출 방지장치가 설치되었다(2.1.절). TB3 주변의 비포화대 CO2 농도(V9~12: 평균 0.136%)는 TB2 관정 주변(V1~8: 평균 1.148%)보다 현저히 낮다(Fig. 8). 관정 케이싱 외부에 시멘팅이 된 TB3 주변 비포화대로 CH4이 유입되지 않아, CO2 농도가 낮다고 결론지을 수 있다. 즉, 관정의 시멘팅 여부가 관정 주변 비포화대의 CO2 증가에 영향을 미치는 것으로 판단된다. 관정의 완결(well completion)의 정도가 관정 주변의 토양으로의 가스 누출의 위험도를 높일 수 있다는 연구 사례는 많이 찾을 수 있다(Bachu and Celia, 2009; Gasda
CH4가 유출되는 관정 주변 비포화대의 CO2는 CH4의 산화에 의해 증가할 수 있다. 본 연구에서는 비포화대의 CO2, N2, O2의 농도의 관계로부터 CO2가 CH4의 산화에 의해서 발생될 수 있음을 밝혔다. 이는 CO2 농도가 높은 지점의 관정의 정두에서 CH4의 농도가 높은 점으로부터 유추할 수 있다. 또한 CO2와 CH4의 시간적인 변화가 뚜렷한 부의 상관관계를 나타내고 있는 점도 CH4의 산화를 지시한다. 반면 CO2의 탄소동위원소는 CH4의 산화기원으로 보기 어려울 정도로 높았는데, 이는 비포화대 CO2가 충진되는 강우에 용해될 경우 δ13CCO2가 높아질 수 있다는 점으로 설명될 수 있다. 비포화대 가스 샘플링 기간 1일 전과 샘플링 기간 중 약 52 mm의 강우가 있었던 점과 CO2, N2, O2농도 간의 관계는 모두 비포화대 가스의 용해를 지시하고 있다.
관정 주변에서 CH4의 산화는 관정의 시멘팅의 여부에 크게 영향을 받았다. 시멘팅이 되어 있지 않은 TB2 관정에서 CO2 농도가 높았으며, 관정에 시멘팅 시공이 되어 있는 TB3 관정 주변 비포화대에서는 CO2 농도가 낮았다. 한편 CO2 플럭스는 예상과 다르게 비포화대 CO2 농도, 정두의 CO2 농도와는 의미있는 상관관계가 나타나지 않았다. 따라서 CH4가 산출되는 관정 주변에서는 ‘CO2 플럭스 모니터링’ 보다는 ‘비포화대의 토양 가스 성분 분석’이 CH4의 산화를 지시할 수 있는 모니터링 방법이라고 할 수 있다.
비록 본 연구에서 사용한 CH4 분석방법의 분석한계가 높은 점, 심도별 가스 농도의 변화를 측정하지 못한 점은 한계로 남으나, 본 연구의 시료채취, 분석 및 해석 방법은 천연가스 개발 관정 주변 환경 모니터링에 활용될 수 있다. 또한 본 연구의 방법은 CO2 지중저장의 주입정과 관측정 주변, 천연가스 저장소 주변, 유류로 오염된 지역의 토양 가스 모니터링, 누출 탐지 등에 응용될 수 있다. 아울러 본 연구의 결과는 가스 개발 관정의 설계 및 시공에 시멘팅의 중요성을 다시 한 번 강조한다.
본 연구는 한국지질자원연구원에서 수행중인 기본과제의 일환으로 수행되었습니다. 현장의 시료채취 및 분석에 도움을 준 이준복씨에게 감사드립니다.
Econ. Environ. Geol. 2022; 55(4): 407-419
Published online August 30, 2022 https://doi.org/10.9719/EEG.2022.55.4.407
Copyright © THE KOREAN SOCIETY OF ECONOMIC AND ENVIRONMENTAL GEOLOGY.
Gitak Chae1,*, Chan Yeong Kim1,2, Gahyeun Ju1, Kwon Gyu Park1, Yul Roh3, Changhyun Lee1, Byoung-Woo Yum1, Gi-Bae Kim4
1Korea Institute of Geoscience and Mineral Resources (KIGAM), Daejeon 34132, Republic of Korea
2Geogreen21, Seoul 08376, South Korea
3Chonnam National University, Gwangju 61186, Republic of Korea
4KNJ engineering Inc., Uiwang-si 16071, Republic of Korea
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided original work is properly cited.
Soil(vadose zone) gas compositions were measured for about 3 days to suggest a method for monitoring and interpreting soil gas data collected around wells from which methane(CH4) is outflowing. The vadose zone gas samples were collected within 1 m around two test wells(TB2 and TB3) at Pohang and analyzed for CO2, CH4, N2 and O2 concentrations in situ. CO2 flux was measured beside TB2. In addition, gas samples from well head in TB2 and atmospheric air samples were collected for comparison. Carbon isotopes of CO2(δ13CCO2) of samples collected on the last day of the study period were analyzed in the laboratory. The two test wells (TB2 and 3) were 12.7 m apart and only TB3 was cemented to the surface. According to the bio-geochemical process-based interpretation, the relationships between CO2 and O2, N2, and N2/O2 of vadose zone gas were plotted between the lines of CH4 oxidation and CO2 dissolution. In addition, the CH4 concentrations of gas samples from the wellhead of the uncemented well (TB2) were 5.2 times higher than the atmospheric CH4 concentration. High CO2 concentrations (average 1.148%) of vadose zone gas around TB2 seemed to be attributed to the oxidation of CH4. On the other hand, the vadose zone CO2 around the cemented well(TB3) showed a relatively low concentration(0.136%). This difference indicates that the vadose zone gas(including CO2) around the CH4 outflowing well were strongly affected by well completion(cementing). This study result can be used to establish strategies for environmental monitoring of soil around natural gas sites, and can be used to monitor leakage around injection and observation wells for CO2 geological storage. In addition, the method of this study is useful for soil monitoring in natural gas storage and oil-contaminated sites.
Keywords methane oxidation, shallow depth gas field, soil CO2, soil gas monitoring, well completion
채기탁1,* · 김찬영1,2 · 주가현1 · 박권규1 · 노열3 · 이창현1 · 염병우1 · 김기배4
1한국지질자원연구원
2지오그린21
3전남대학교
4KNJ 엔지니어링(주)
메탄(CH4)이 유출되는 관정 주변에서 토양(비포화대) 가스 모니터링과 자료 해석 방법을 제시하고자 토양 가스의 성분변화를 약 3일간 측정하였다. 이를 위해서 포항 지역의 시험 관정 2개(TB2, TB3)의 주변 1 m 이내에서 방사상으로 토양 가스를 채취하고 현장에서 CO2, CH4, N2, O2의 농도를 분석하였다. TB2의 관정 정두(wellhead)에서 30 cm 떨어진 지점에서 CO2 플럭스도 측정하였다. 아울러 TB2 관정 정두의 가스 시료와 대기 시료도 채취하여 분석하였다. 모니터링 마지막 날 채취한 시료는 실험실에서 CO2의 탄소동위원소(δ13CCO2)를 분석하였다. 서로 12.7 m 떨어져 있는 두 시험 관정 중 TB3는 시멘팅이 되어 있고, TB2는 시멘팅이 되어 있지 않았다. 생지구화학 반응 기반(process-based) 해석을 적용한 결과, 비포화대 가스의 CO2, O2, N2 농도와 N2/O2 의 변화는 모두 CH4의 산화를 지시하는 선과 가스의 용해에 의한 농도의 변화를 지시하는 선 사이에 위치하고 있었다. 또한 TB2 정두에서 측정된 CH4은 대기의 CH4에 비해서 5.2배 높은 값을 나타나고 있었다. 시멘팅이 되어 있지 않은 관정(TB2) 주변 비포화대에서 나타난 높은 CO2 농도(평균 1.148%)는 CH4의 산화에 의해 증가한 것으로 판단된다. 반면, 시멘팅이 된 관정(TB3) 주변의 비포화대 CO2는 상대적으로 낮은 농도(0.136%)를 나타내고 있었다. 따라서 CH4가 산출되는 관정의 주변 토양가스(CO2 포함)는 관정의 완결 상태(시멘팅)에 크게 영향을 받는 것으로 판단된다. 본 연구는 천연가스 개발 관정 주변 토양의 환경 모니터링을 위한 전략 수립에 활용될 수 있으며, CO2 지중저장을 위한 주입정 및 관측정 주변 누출 감시에 활용될 수 있다. 또한 본 연구의 방법은 천연가스 저장소, 유류 오염 토양의 모니터링에 활용 가치가 있다.
주요어 메탄 산화, 천부 육상 가스전, 토양 CO2, 토양 가스 모니터링, 관정 완결
Soil CO2 could be originated from CH4 oxidation around wells discharging CH4, which is strongly affected by well completion.
Negative relationships between CO2 and CH4 in soil gas with time showed CH4 oxidation.
The relationships between CO2 and O2, N2, and N2/O2 of soil gas revealed that CO2 dissolved in rain water after CH4 oxidation.
비포화대(토양)는 지질권, 생물권, 대기권이 겹쳐있는 경계로서 다양한 환경-지구화학 반응이 발생하는 복잡한 시스템이다. 게다가 인간의 생활, 산업, 농업 활동에 영향을 주고받으며 심각한 변화를 겪고 있다. 특히 비포화대의 가스는 자연적이든 인위적이든 지질권에서 배출되는 가스가 최종적으로 거치는 통로이며, 대기와 소통하고, 생물의 활동에 의해 변화하며, 반대로 생물의 활동에도 영향을 준다. 그동안 지질학 분야에서 비포화대 가스에 관한 연구는 주로 화산 감시와 화산 가스의 총 배출량을 추정하기 위해 수행되었다. 최근에는 화산 관련 연구에서 개발된 비포화대 가스 연구 방법이 이산화탄소지중저장 관련 연구, 단층지역 가스 유동 연구에 응용되었다(Jones
본 연구는 CO2 지중저장 모니터링 관련 시험을 위해 시공된 관정 주변(Fig. 1의 TB2와 TB3)의 비포화대 가스를 조사하는 중에 관정 정두에서 메탄가스(CH4)가 관찰되었으며, 이에 의한 비포화대 CO2의 변화가 인지되어 시작되었다. 우리나라 육상에서는 대규모의 가스전이 발견된 사례가 없어서, 가스 개발 관정 주변 환경 모니터링에 대한 필요성이 없었다. 그러나 2017년 3월 포항시 남구에 공원 조성을 위해 지하수 관정을 굴착하던 중에 천연가스에 의한 화재가 발생하여 소규모 육상 가스전이 확인되었다(신정균 외, 2019; 황인걸 외, 2019). 포항 일대에서는 지하수에서 메탄의 부존이 드물지 않게 보고되었으나(Lee
메탄가스 생산 관정 주변의 토양에서는 CH4의 산화에 의해 CO2 농도가 증가할 가능성이 있다. Romanak
본 연구는 CH4가 부존된 지역에서 토양 가스 모니터링과 해석 방법을 제시하고자 수행되었다. 이를 위해서 CH4가 배출되는 것으로 의심되는 시험 관정 주변의 약 1 m 내외에서 비포화대 가스 시료를 채취하여 성분 및 탄소동위원소를 약 3일간 3시간 간격으로 분석하였다. 이 연구는 우리나라에서는 처음으로 CH4 부존 지역의 토양가스를 연구한 결과이며, 연구 결과는 CO2 지중저장 관련 사업, 천연가스 저장소 주변 토양, 유류로 오염된 토양의 가스 모니터링 방법에 응용될 수 있을 것으로 기대된다.
연구 지역은 경상북도 포항시 북구 흥해읍 성곡리에 위치한 한국지질자원연구원 포항지질자원실증연구센터 내에 조성된 시험 부지로, TB2와 TB3 관정 주변이다(Fig. 1a). 연구지역은 제 3기 마이오세 반고결 이암층으로 이루져 있는 두호층에 분포하며, 두호층 하부에는 제 3기 에오세 쇄설성 화산암류가, 더 아래로는 백악기 기반암(안산암질 화산암류 및 쇄설성 퇴적암류)이 존재한다. TB2의 시추코어를 분석한 결과 전체적으로 회색을 띠는 이암이 우세하게 존재하는 가운데, 고화도가 불량한 사질층과, 역을 포함하는 사질층이 협재한다(KIGAM, 2014). 지표로부터 87 ~ 93 m, 235 ~ 238 m, 307 ~ 312 m 심도에 사질층이 협재한 구간이 시추코어에서 확인되었다. Lee
TB2와 TB3는 시험 관정으로서, 약 12.7 m 떨어져 있다. TB2 관정의 총 심도는 329.7 m 이고, 302.7 m 하부는 스크린이 설치되어 있다. TB2 관정은 바닥까지 케이싱이 설치되었고, 케이싱 외부는 시멘팅이 안 되어 있다. TB3 관정은 총 심도가 405 m 이고 하부까지 케이싱이 설치되었다. 320 m 하부에 스크린이 설치되어 있고, 심도 150 m 까지는 gravel packing이 되었으며, 150 m 상부는 시멘팅이 되어 있다. TB3는 케이싱 상부 정두에 가스의 누출 방지장치가 설치되어 있다.
연구 기간(2019년 4월 27일부터 30일) 7일 전(4월 20일)부터 연구 종료 때까지 기상자료를 Fig. 1b에 도시하였다. 기상자료는 연구지역과 가장 가까운 기상청의 포항 AWS(automatic weather system) 자료이다. 연구 시작 직전인 4월 26일은 6.3 mm의 약한 강우가 있었고, 27일 새벽 2시 30분에 그쳤다. 그리고 4월 29일 11시 20분에 강우가 시작되어 29일 23시까지 45.9 mm의 비교적 강한 강우가 있었다(Fig. 1b). 27일에는 비가 그친지 7시간 30분 후에 시료채취 및 분석을 시작하였고, 29일과 30일에는 비가 그친지 11시간 후에 시료채취 및 분석을 재개하였다. 따라서 본 연구 기간은 토양 가스가 강우의 영향을 받은 기간에 수행되었다고 할 수 있다.
연구 기간 중 기온은 9.6 ~ 18.3 °C, 상대습도는 44.6 ~ 100.0%, 해면기압은 1007.3 ~ 1023.3 hPa로 변화를 보였다. 특히 기압은 연구 기간 내내 감소하는 추세를 나타내었다. 기온, 상대습도, 기압은 CO2 플럭스 측정 시 동시에 측정되기 때문에 AWS 자료보다는 현장에서 측정된 값을 해석에 이용하였다(2.3절 참조).
비포화대 가스는 2019년 4월 27일 오전 10시부터 30일 19시까지 3시간 간격으로 21회 채취하였다. 4월 29일 오전 11시부터 비가 오기 시작하여 7회(24시간) 시료 채취를 못하였으며, 4월 30일 10시부터 재개하여 19시에 종료하였다. 비포화대 가스 시료 채취를 위해서 AMS gas probe(AMS, Inc., USA)를 이용해서 약 60.4(±2.6) cm를 굴착하여 비포화대 가스 샘플링관(PFA(perfluoroalkoxy)재질, ID 0.44 cm)을 시료 채취 하루 전(4월 26일)에 설치하였다(Fig. 1a). 관정 주변은 잔돌로 약 50 cm 덮여있었기 때문에 잔돌 층을 제거하고 AMS gas probe를 설치하였다. 비포화대 가스 샘플링관 끝에는 화살촉 모양의 스테인리스 재질의 첨두가 있고, 이는 토양 입자의 유입을 방지하기 위한 스테인리스 망(mesh #50)으로 감싸여있다. 또한 지표의 대기 유입을 막기 위해서 fluoropolymer 재질의 둥글고 얇은 우산모양 판을 샘플링관과 첨두 사이에 설치하였다. 샘플링관은 TB2 관정 주변에 12개, TB3 관정 주변에 4개 설치되었다(Fig. 1a). TB2 주변에 설치된 샘플링관은 북쪽에서부터 시계 방향으로 V1부터 V8로 명명하였으며, TB3 주변의 샘플링관은 북쪽에서부터 시계방향으로 V9부터 V12로 명명하였다(Fig. 1a).
비포화대 가스는 설치된 샘플링관을 통해 지상에서 연동펌프(Masterflex E/S, Cole-Parmer Instrument, USA)로 1분간 관 내부에 고인 가스를 제거한(purging) 후 약 50 mL를 Tedlar bag에 담았다. 연동펌프의 유량은 약 80 mL/min으로 유지하였다. 시료 채취는 3시간 간격으로 정시에 1번 관(V1)부터 시작하여 12번 관(V12)까지 수행되었으며, 1회 소요 시간은 약 30분 정도 걸렸다. V12에서는 물이 유입되어 연구 기간의 마지막에만 시료를 채취/분석하였다.
본 연구에서는 비포화대 가스 외에 TB2 관정의 정두에서 가스를 채취하였으며, 비포화대 가스와 대기가 혼합되었는지 파악하기 위하여 대기 시료도 채취 하였다. 정두 가스 시료는 정두의 관정 캐이싱 내부에 시료 채취용 튜브를 약 20 cm 넣어 채취하였고, 대기 시료는 TB2 위치에서 지상 약 100 cm 상부에서 채취되었다. 정두 가스 시료는 비포화대 가스 시료 채취 시 매번 채취하였으나, 대기 시료는 약 12시간마다 한 번 채취(6회)하였다.
비포화대 가스, TB2 관정의 정두 가스, 대기 시료의 주요 성분인 N2, O2, CO2, CH4의 농도는 QMS(quadrupole mass spectrometer: Pfeiffer Vacuum, 독일) OmnistarTM(GSD320 gas analysis system)를 활용하여 현장에서 시료 채취 후 즉시 분석하였다. QMS 장비의 기체 시료 주입관에 Tedlar bag을 연결한 후, 5분 이상 가스를 흘려주고 마지막의 농도 값을 읽어 기록하였다. QMS는 가스 질량분석기로서 장비에 주입된 가스를 구성하는 분자를 이온화 하고, 4중극자 질량 필터(quadropole mass filter)에서 가스의 각 이온을 질량/전하 비율(mass/charge)로 분리하여 이온 검출기(ion detector)로 각 이온의 이온 전류(ion current)를 측정한다. 측정된 이온 전류는 표준시료로 보정을 거쳐 부피%로 나타낸다. 본 연구에서는 국내에서 제조된 표준가스시료(N2 = 74.02%, O2 = 19.98%, CO2= 5.00%, CH4 = 1.00% Rigas©, Korea)로 보정하였으며, 표준시료를 9회 분석하여 보정 값을 유지하고 있는지 확인하였다. 그 결과 N2, O2, CO2는 각각 0.1%, 0.5%, 0.5% 정도만 참값에서 벗어났고, CV(coefficient of variation)는 각각 0.4%, 0.7%, 1.5%로 정밀도가 매우 좋았다.
반면 CH4는 보정 후 표준시료 분석에서 평균 4.9% 벗어나 있으며, CV는 10.4%로 상대적으로 정밀도가 떨어졌다. CH4의 이온화된 가스 분자의 주된 amu(atomic mass unit)는 16, 15(amu 16에 대한 이온강도 비율 85.8%)인데 amu 16의 경우 CH4가 O2, CO2, H2O 등과 amu를 공유하고 있으므로 O2, CO2, H2O의 성분이 높은 혼합 가스의 경우 CH4가 과평가 될 수 있다. 따라서 CH4는 amu 15로 분석하였다(Freifeld and Trautz, 2006). 이와 같이 QMS 분석에서는 한 종류의 가스분자에서 파생된 amu가 다른 분자와 동일한 amu를 나타낼 수 있으므로, 다성분 가스와 여러 원소로 구성된 가스, 질량이 무거운 가스가 많을수록, 가벼운 가스 성분의 농도 측정에 영향을 미칠수가 있다. 초고순도 N2를 공시료(blank sample)로서 분석한 CH4의 기기검출한계(IDL: instrument detection limit)는 0.014%이다. 이는 일반적인 대기의 CH4 농도인 1.7 ~ 1.9 ppmv(NOAA, 2022; Wuebbles and Hayhoe, 2002)에 비해서 높은 값이다. 따라서 본 연구에서는 토양 CH4의 농도(S)를 현장에서 측정한 대기 CH4 농도(A)의 비례값(S/ACH4)으로 나타내었다. 본 연구의 주안점은 토양 CO2 모니터링이기 때문에 토양 CH4에 대해서는 정량적인 해석보다는 CO2 농도에 연관하여 정성적으로 해석하였다.
연구 기간의 마지막 날(2019년 4월 30일 19:00) 채취한 비포화대 가스 시료는 대전의 한국지질자원연구원으로 운송하여 탄소동위원소(δ13CCO2)를 분석하였다. CO2의 탄소 동위원소 분석은 CRDS(cavity ringdown spectroscopy: Picarro 사(社) G2121-i)를 이용하였으며(Park
지표에서 배출되는 CO2의 유량인 플럭스는 미국 Li-COR 사의 Li-8100A로 측정하였다(Park
본 연구에 활용된 통계분석은 통계 프로그램 R로 수행하였다(R core team, 2018). 두 변수간의 선형관계는 상관분석(correlation analysis)을 통하여 수행하였고, 상관계수(r)로 나타내었다. 상관분석은 조사기간 초기 결측값을 제외하고 강우 이전인 4월 27일 16시부터 29일 10시까지 자료들을 대상으로 하였다.
그룹간의 차이를 정량적으로 평가하기 위해 Mann-Whiteny U test를 수행하였다. Mann-Whiteny U test는 독립적인 두 그룹의 자료의 순위를 각각 구한 후 순위의 평균을 비교하는 비모수 통계분석이다(Chae
TB2와 TB3 주변의 심도 약 60 cm 비포화대에서 채취된 가스 시료, TB2 관정 정두에서 채취된 가스 시료, 대기 시료의 QMS 및 CRDS 분석 결과의 기초 통계를 Table 1에 나타내었다. 비포화대의 CO2 평균은 0.871%이고, 최대값은 2.612%(=26,120 ppmv)이다. 특징적으로 비포화대 N2(평균 80.1%)는 대기(78.7%)보다 높고, O2(19.0%)는 대기(21.2%) 보다 낮다. TB2 인근 비포화대(V1~8) CO2 평균은 1.148(±0.205%), TB3인근 비포화대(V9~10) 평균은 0.136(±0.088%)로 뚜렷하게 구분된다. 비포화대 가스의 S/ACH4(대기 CH4에 대한 비율) 평균은 1.0이고, 0.8 ~ 1.2 사이에서 변화한다. 비포화대의 CH4 농도는 대기와 비슷한 수준인 것으로 평가된다. TB2 주변의 S/ACH4 는 1.0이고, TB3 주변은 0.9이다(Table 1). Mann-Whitney U test 결과 p 값은 0.000(2.85E-5)으로 TB2가 TB3 보다는 높다고 평가 할 수 있다.
Table 1 . Statistics of vadose zone gas, wellhead gas, and air samples collected around test wells in Pohang area.
CO2(%) | S/ACH41) | N2(%) | O2(%) | δ13CCO2(‰)2) | ||
---|---|---|---|---|---|---|
Vadose | Average | 0.871 | 1.0 | 80.1 | 19.0 | -18.0 |
zone gas | Stdev.3) | 0.725 | 0.1 | 1.5 | 2.2 | 8.0 |
(n=232) | Minimum | 0.059 | 0.8 | 78.0 | 12.1 | -25.2 |
Maximum | 2.612 | 1.2 | 85.3 | 21.5 | -4.1 | |
Vadose zone gas around TB2 | Average | 1.148 | 1.0 | 80.6 | 18.3 | -23.2 |
Vadose zone gas around TB3 | Average | 0.136 | 0.9 | 78.8 | 21.1 | -7.5 |
Wellhead | Average | 0.076 | 5.2 | 78.7 | 21.1 | |
gas at TB2 | Stdev.3) | 0.015 | 3.5 | 0.1 | 0.2 | |
(n=19) | Minimum | 0.065 | 1.6 | 78.2 | 20.7 | |
Maximum | 0.136 | 14.0 | 78.9 | 21.6 | ||
Air | Average | 0.081 | 1.0 | 78.7 | 21.2 | -9.2 |
(n=6) | Stdev.3) | 0.071 | 0.1 | 0.1 | 0.1 | |
Minimum | 0.068 | 0.9 | 78.6 | 21.2 | ||
Maximum | 0.114 | 1.1 | 78.7 | 21.4 |
1) The ratio of CH4 concentration to the average CH4 of air samples..
2) Carbon-13 isotope of CO2 expressed in the δ(‰) notation relative to the V-PDB(Vienna Peedee Belemnite) standard..
3) Standard deviation..
조사의 마지막(2019년 4월 30일 19:00)에 채취된 비포화대 가스의 δ13CCO2는 평균 –18.0‰(–25.2 ~ -4.1‰)로 나타났다. TB2 인근 V1~8의 평균은 –23.2(±2.0‰), TB3 인근 V9~10의 평균은 –7.5(±2.8‰)로 CO2 농도와 마찬가지로 뚜렷하게 구분된다. 최대값인 –4.1‰(V10)은 대기 시료의 δ13CCO2(–9.2‰)보다 높은 특징이 있다. TB2의 정두에서 채취된 가스의 CO2 평균은 0.076%이고, S/ACH4의 평균은 5.2로 대기보다 5배 높은 CH4 농도를 나타낸다(Table 1). 대기의 CO2 평균 농도는 0.081%로 정두에서 측정된 CO2 농도와 차이나지 않았다(Mann-Whitney U test 결과 p = 0.333).
TB2 관정에서 30 cm 떨어진 곳에서 측정된 CO2 플럭스의 평균은 3.5 g/m2/d이다(Table 2). 시간에 따른 플럭스의 변화는 3.2.2절에 설명되어 있다. CO2 플럭스 측정중에 동시에 측정된 surface CO2의 평균은 0.048%로 QMS로 분석된 대기 CO2의 평균값(0.081%)보다 낮다. QMS로 분석한 CO2는 5.0% 표준시료로 보정한 값이다. 따라서 0.1% 미만의 낮은 CO2 농도는 분석기기의 오차가 반영되었을 수 있다. Fig. 2에서 제시된 CRDS와 QMS의 CO2 농도 상관관계 식(CRDS = 0.9921 × QMS – 0.022)에서 QMS 분석 결과가 CRDS 분석 결과에 비해 약 0.02% 높게 측정되었음을 알 수 있다. CO2 플럭스 측정 전에 측정된 대기의 온도(Temp.)는 10.5oC에서 23.9°C(평균 14.5°C), 상대습도(RH)는 36.2%에서 89.7%(평균 68.0%)로 일교차가 심하였다(Table 2). CO2 플럭스 측정 중에 측정된 챔버 내부의 대기압(Ps)은 982.4 hPa에서 997.9 hPa 범위를 나타냈으며, TB2의 지하수위 심도는 25.36 m에서 25.52 m로 16 cm 변동하였다(Table 2).
Table 2 . Statistics of CO2 flux measured beside the test well (TB2) in Pohang (n=19). Surface CO2, temperature, relative humidity, air pressure were also measured during CO2 flux measurement.
CO2 flux (g/m2/d) | Surface CO21)(%) | Temp.2)(°C) | RH3)(%) | Ps4)(hPa) | Depth to water table of TB2 (m) (n=22) | |
---|---|---|---|---|---|---|
Average | 3.5 | 0.048 | 14.5 | 68.0 | 992.8 | 25.44 |
Stdev.5) | 1.0 | 0.002 | 3.5 | 13.2 | 5.0 | 0.04 |
Minimum | 2.2 | 0.046 | 10.5 | 36.2 | 982.4 | 25.36 |
Maximum | 5.3 | 0.051 | 23.9 | 89.7 | 997.9 | 25.52 |
1) The average CO2 concentration measured for 2 minutes during CO2 flux measurement..
2) Air temperature measured in the pre-purging stage before CO2 flux measurement, which represents the atmospheric temperature..
3) Relative humidity measured in the pre-purging stage before CO2 flux measurement, which represents the atmospheric relative humidity..
4) The average air pressure measured for 2 minutes during CO2 flux measurement. Since the pressure inside the chamber remains constant during the CO2 flux measurement, this value can be considered as the air pressure measured in the field..
5) Standard deviation..
TB2와 TB3 주변의 비포화대 CO2의 농도를 Fig. 3a에 나타내었다. TB2 주변 V1~8은 4월 28일 19시 이전에는 공통적인 경향이 뚜렷하지 않았으나, 4월 28일 19시 이후부터 일률적으로 증가하는 양상을 나타냈다(Fig. 3a). 비가 그친 4월 30일 10시 이후에는 V1~8 간에 공통적인 경향이 나타나지 않았다. Fig. 3c에는 V1~8의 평균과 표준편차를 나타내었다. 4월 28일 19시 이후부터 표준편차가 줄어드는 것을 확인할 수 있다. 표준편차가 크지만 대체로 매일 16시까지 비포화대 CO2는 감소하다가 16시 이후부터 다음날 오전 10시까지 증가한 후 다시 감소하는 일변화 경향을 나타낸다(Fig. 3c).
비포화대 S/ACH4의 변화를 Fig. 3b에 나타내었다. S/ACH4는 시간에 따라 감소하는 경향을 나타내다가 비가 그친 후(4월 30일 10시) 다시 증가한다. CO2에 비하여 가스 시료 채취 위치 간의 차이가 적다. Fig. 3c에는 TB2 인근 V1~8의 S/ACH4 평균과 표준편차를 나타내었다. 그 결과 CO2의 변화와는 약간의 시간차를 두고 반대로 나타나고 있다. CO2와 S/ACH4의 상관계수는 –0.74(p<0.05)이다.
비포화대 N2와 O2 의 변화를 Fig. 3d와 e에 각각 나타내었다. Fig. 3f에는 V1~8까지의 평균과 표준편차를 나
타내었다. N2는 야간에 증가하고 주간에 감소하여 CO2와 유사한 변화를 나타내고, O2의 농도는 그 반대의 경향을 나타내고 있다. V1~8 평균 N2와 CO2의 상관계수(correlation coefficient, r)는 0.96(p<0.05), O2와 CO2의 상관계수는 –0.98(p<.05)이다. 비포화대의 CO2, S/ACH4, N2, O2 가스 성분의 변화는 서로 밀접한 상관관계가 있다.
정두에서 채취된 가스 시료의 시간에 따른 변화는 Fig. 4에 나타내었다. CO2 농도는 4월 29일 4시에 0.136%를 제외하면 비교적 일정하게 유지되었다(Fig. 4a). 반면 S/ACH4, N2, O2 농도는 시간에 따라 증감하는 양상이 나타난다(Fig. 4a, b). S/ACH4는 N2와 정의 상관성(r=0.59, p<0.05), O2와 부의 상관성(r=-0.91, p<0.05)을 나타내었다.
시간에 따른 CO2 플럭스의 변화와 플럭스 측정기로 측정된 surface CO2, 대기의 온도(Temp.)와 상대 습도(RH), 압력(Ps) 및 TB2의 지하수위 심도를 Fig. 5에 나타내었다. CO2 플럭스는 주간에 증가하고, 야간에 감소하는 일변화를 나타낸다(Fig. 5a). CO2 플럭스는 surface CO2와는 부의 관계(Fig. 5a, r=-0.51, p<0.05), 대기 온도와는 정의 관계(Fig. 5b, r=0.39, p=0.15), 대기 상대 습도와는 부의 관계(Fig. 5c, r=-0.56, p<0.05), TB2 지하수 수위 심도와는 부의 관계(Fig. 5e, r=-0.26, p=0.34)를 나타낸다. CO2 플럭스와 온도, 수위 심도는 Fig. 5b와 5e에서는 상관관계가 있는 것으로 보이나 상관계수는 낮게 나타났다. 상관계수는 2.4장에서 설명하였듯이, 비가 온 기간과 조사 초기 시점의 결측값을 제외한 통계분석 결과이어서 그래프에서 보이는 것보다 상관관계가 낮게 평가된 것으로 판단된다.
연구 지역 TB2, TB3 관정 인근 비포화대에서 채취된 가스의 CO2-O2, N2-CO2, N2/O2-CO2 간의 관계를 Fig. 6에 나타내었다. Fig. 6은 Romanak
CH2O + O2 = CO2 + H2O (식 1)
CH4 + 2O2 = CO2 + 2H2O (식 2)
Fig. 6에서 비포화대 가스 성분은 미생물의 호흡(biological respiration)을 나타내는 지시선보다 메탄 산화(oxidation of CH4)를 나타내는 지시선에 더 가깝다. 게다가 정두에서 채취된 가스의 CH4는 대기의 CH4보다 평균 5.2배 높고, 최대 14배 높게 나타났다(Table 1). 대기의 CH4가 1.8 ppmv이라고 한다면, 정두에서 측정된 CH4는 250 ppmv 정도로 높다. 따라서 CH4가 산화되어 CO2가 발생했을 가능성이 충분하다. Romanak
본 연구에서 분석한 비포화대 CH4 농도는 분석 한계에 근접한 값을 나타냈기 때문에 대기 시료의 CH4 평균값에 대한 비율(S/ACH4)로 해석하였다(2.2.3 절 참조). Romanak
토양 미생물이 O2로 호흡을 하고 C3 식물을 분해하는 대사과정(식 1)에서 발생한 CO2의 탄소동위원소는 -34 ∼ -23‰ 범위로 알려져 있다(Faure, 1998). TB2 주변 비포화대 CO2의 δ13CCO2의 평균값은 –23.2‰ 이기 때문에 CO2의 기원을 미생물의 호흡으로 해석할 수도 있다. CH4 산화가 발생하면 용존 CO2의 탄소동위원소는 값은 오히려 낮아지는 것으로 알려져 있다(Clark and Fritz, 1997; Kotelnikova, 2002). Park
CH4 산화로 생성된 CO2가 충진되는 강우에 용해되어 δ13CCO2가 높아졌을 가능성이 있다. 토양으로 충진되는 강우의 pH를 측정하지는 못 했으나(4월 26일 ~ 27일), pH가 5.5보다 낮을 경우 εDIC-CO2는 약 –1‰(14.5oC) 정도이기 때문에(Chae
앞서 설명한 바와 같이 발생된 CO2는 토양층을 거처 지하수로 충진되는 강우에 용해될 수 있다(Romanak
혼합되는 정도에 따라서 가스 성분의 농도가 결정되는 것으로 판단된다.
한편, TB3 주변 비포화대의 CO2는 CH4의 산화가 아닌 대기와의 혼합이 크게 영향을 미쳤다고 할 수 있다. 그러나 TB3 인근 비포화대의 δ13CCO2는 1개 시료를 제외하고 모두 대기 시료의 –9.2‰보다 높다(Fig. 7). 이는 4.2 절에서 설명한 바와 같이 open system에서 CO2의 용해에 의해 잔류 CO2의 동위원소 값이 높아진 것으로 판단된다. TB3 주변의 비포화대 가스의 CO2 농도는 TB2보다 낮고(Fig. 8), V9를 제외하면 대기의 CO2 농도와 비슷하다. 따라서 TB3 주변 비포화대 CO2는 CH4의 산화나 미생물의 호흡에 의한 CO2 보다는 대기의 혼합 비율이 높고, 강우에 용해된 결과로 판단된다.
한편 용존 CH4는 미생물에 의해 산소와 황산염이온과 반응하여 산화 될 가능성이 있다(Clark and Fritz, 1997; 식 3, 4). CH4 + 2O2 = HCO3- + H2O + H+ (식 3) CH4 + SO42- = HCO3- + HS- + H2O (식 4) 2017년 9월 5일 심도 약 300 m에서 채취된 TB2 관정의 물 시료의 용존산소는 2.2 mg/L, SO4 이온은 258 mg/L 로 분석된 바 있다. 특히 HS- 농도가 4 μg/L로 나타난 바 있다. 따라서 용존 CH4이 산화되어 용존 탄산염이 되고(식 3, 4), 용존 탄산염이 탈기되어 비포화대에 유입될 가능성도 고려해 볼 필요가 있다. 그러나 물 시료의 pH가 9.0이고, DIC가 0.5 mmol/L, PCO2가 0.03 atm으로 낮은 점으로 보아 용존 CH4가 산화되었다고 해도 CO2가 탈기되어 대수층에서 비포화대로 이동했을 가능성은 없다. 게다가 연구지역의 지표 부근은 두꺼운 이암층(2.1.절)이 분포하고 있어서 대수층에서 탈기에 의해 CO2가 비포화대로 유입될 가능성은 낮은 것으로 판단한다. 따라서 본 연구에서 TB2 관정 인근 비포화대의 CO2는 TB2 관정에 고인 물에서 탈기된 CH4이 산화되어 CO2가 되고, CO2가 주변 비포화대로 퍼진 결과로 판단된다. 특히 TB2 관정의 수위심도는 25.4 m로 낮고(Fig. 5e), 관정 케이싱 외부에 시멘팅이 안 되어 있는 점은 위 주장에 신빙성을 더하고 있다.
반면 TB3 관정은 바닥에서 상부까지 시멘팅이 되어 있고 정두에 누출 방지장치가 설치되었다(2.1.절). TB3 주변의 비포화대 CO2 농도(V9~12: 평균 0.136%)는 TB2 관정 주변(V1~8: 평균 1.148%)보다 현저히 낮다(Fig. 8). 관정 케이싱 외부에 시멘팅이 된 TB3 주변 비포화대로 CH4이 유입되지 않아, CO2 농도가 낮다고 결론지을 수 있다. 즉, 관정의 시멘팅 여부가 관정 주변 비포화대의 CO2 증가에 영향을 미치는 것으로 판단된다. 관정의 완결(well completion)의 정도가 관정 주변의 토양으로의 가스 누출의 위험도를 높일 수 있다는 연구 사례는 많이 찾을 수 있다(Bachu and Celia, 2009; Gasda
CH4가 유출되는 관정 주변 비포화대의 CO2는 CH4의 산화에 의해 증가할 수 있다. 본 연구에서는 비포화대의 CO2, N2, O2의 농도의 관계로부터 CO2가 CH4의 산화에 의해서 발생될 수 있음을 밝혔다. 이는 CO2 농도가 높은 지점의 관정의 정두에서 CH4의 농도가 높은 점으로부터 유추할 수 있다. 또한 CO2와 CH4의 시간적인 변화가 뚜렷한 부의 상관관계를 나타내고 있는 점도 CH4의 산화를 지시한다. 반면 CO2의 탄소동위원소는 CH4의 산화기원으로 보기 어려울 정도로 높았는데, 이는 비포화대 CO2가 충진되는 강우에 용해될 경우 δ13CCO2가 높아질 수 있다는 점으로 설명될 수 있다. 비포화대 가스 샘플링 기간 1일 전과 샘플링 기간 중 약 52 mm의 강우가 있었던 점과 CO2, N2, O2농도 간의 관계는 모두 비포화대 가스의 용해를 지시하고 있다.
관정 주변에서 CH4의 산화는 관정의 시멘팅의 여부에 크게 영향을 받았다. 시멘팅이 되어 있지 않은 TB2 관정에서 CO2 농도가 높았으며, 관정에 시멘팅 시공이 되어 있는 TB3 관정 주변 비포화대에서는 CO2 농도가 낮았다. 한편 CO2 플럭스는 예상과 다르게 비포화대 CO2 농도, 정두의 CO2 농도와는 의미있는 상관관계가 나타나지 않았다. 따라서 CH4가 산출되는 관정 주변에서는 ‘CO2 플럭스 모니터링’ 보다는 ‘비포화대의 토양 가스 성분 분석’이 CH4의 산화를 지시할 수 있는 모니터링 방법이라고 할 수 있다.
비록 본 연구에서 사용한 CH4 분석방법의 분석한계가 높은 점, 심도별 가스 농도의 변화를 측정하지 못한 점은 한계로 남으나, 본 연구의 시료채취, 분석 및 해석 방법은 천연가스 개발 관정 주변 환경 모니터링에 활용될 수 있다. 또한 본 연구의 방법은 CO2 지중저장의 주입정과 관측정 주변, 천연가스 저장소 주변, 유류로 오염된 지역의 토양 가스 모니터링, 누출 탐지 등에 응용될 수 있다. 아울러 본 연구의 결과는 가스 개발 관정의 설계 및 시공에 시멘팅의 중요성을 다시 한 번 강조한다.
본 연구는 한국지질자원연구원에서 수행중인 기본과제의 일환으로 수행되었습니다. 현장의 시료채취 및 분석에 도움을 준 이준복씨에게 감사드립니다.
Table 1 . Statistics of vadose zone gas, wellhead gas, and air samples collected around test wells in Pohang area.
CO2(%) | S/ACH41) | N2(%) | O2(%) | δ13CCO2(‰)2) | ||
---|---|---|---|---|---|---|
Vadose | Average | 0.871 | 1.0 | 80.1 | 19.0 | -18.0 |
zone gas | Stdev.3) | 0.725 | 0.1 | 1.5 | 2.2 | 8.0 |
(n=232) | Minimum | 0.059 | 0.8 | 78.0 | 12.1 | -25.2 |
Maximum | 2.612 | 1.2 | 85.3 | 21.5 | -4.1 | |
Vadose zone gas around TB2 | Average | 1.148 | 1.0 | 80.6 | 18.3 | -23.2 |
Vadose zone gas around TB3 | Average | 0.136 | 0.9 | 78.8 | 21.1 | -7.5 |
Wellhead | Average | 0.076 | 5.2 | 78.7 | 21.1 | |
gas at TB2 | Stdev.3) | 0.015 | 3.5 | 0.1 | 0.2 | |
(n=19) | Minimum | 0.065 | 1.6 | 78.2 | 20.7 | |
Maximum | 0.136 | 14.0 | 78.9 | 21.6 | ||
Air | Average | 0.081 | 1.0 | 78.7 | 21.2 | -9.2 |
(n=6) | Stdev.3) | 0.071 | 0.1 | 0.1 | 0.1 | |
Minimum | 0.068 | 0.9 | 78.6 | 21.2 | ||
Maximum | 0.114 | 1.1 | 78.7 | 21.4 |
1) The ratio of CH4 concentration to the average CH4 of air samples..
2) Carbon-13 isotope of CO2 expressed in the δ(‰) notation relative to the V-PDB(Vienna Peedee Belemnite) standard..
3) Standard deviation..
Table 2 . Statistics of CO2 flux measured beside the test well (TB2) in Pohang (n=19). Surface CO2, temperature, relative humidity, air pressure were also measured during CO2 flux measurement.
CO2 flux (g/m2/d) | Surface CO21)(%) | Temp.2)(°C) | RH3)(%) | Ps4)(hPa) | Depth to water table of TB2 (m) (n=22) | |
---|---|---|---|---|---|---|
Average | 3.5 | 0.048 | 14.5 | 68.0 | 992.8 | 25.44 |
Stdev.5) | 1.0 | 0.002 | 3.5 | 13.2 | 5.0 | 0.04 |
Minimum | 2.2 | 0.046 | 10.5 | 36.2 | 982.4 | 25.36 |
Maximum | 5.3 | 0.051 | 23.9 | 89.7 | 997.9 | 25.52 |
1) The average CO2 concentration measured for 2 minutes during CO2 flux measurement..
2) Air temperature measured in the pre-purging stage before CO2 flux measurement, which represents the atmospheric temperature..
3) Relative humidity measured in the pre-purging stage before CO2 flux measurement, which represents the atmospheric relative humidity..
4) The average air pressure measured for 2 minutes during CO2 flux measurement. Since the pressure inside the chamber remains constant during the CO2 flux measurement, this value can be considered as the air pressure measured in the field..
5) Standard deviation..